DOB filing X01248152-I1
Alteration filing at 455 Southern Boulevard
Building record · BIN 2003883
455 Southern Boulevard, Bronx, NY 10455
A consolidated, filing-by-filing view of DOB records matched to this building identifier. The current snapshot links 5 independently sourced records, including 5 that are not recorded as completed, closed or withdrawn.
BUILDING RECORD · BIN 2003883
455 Southern Boulevard
Mott Haven-Port Morris, Bronx
A consolidated public-record view · updated Sep 8, 2026
A building-level summary of matched filings, active-status records and published identifiers.
The lot
The lot holds a 3-story educational building built in 1931, on a 85,000 sq ft lot.
Lot facts come from NYC Department of City Planning, Primary Land Use Tax Lot Output (PLUTO) (64uk-42ks), accessed Sep 10, 2026. They describe the tax lot, not any single filing. When the rest of New York went up
Violation record
The Department of Buildings has 12 open notices on record for this building, out of 114 notices on file; the most recent was issued Nov 14, 2025.
Issued Nov 14, 2025 — VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION
Issued Nov 14, 2025 — VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION
Issued Nov 14, 2025 — VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION
9 further open notices are on file. Open the source dataset for the full list.
Open means the agency has not recorded a resolution, which is not the same as the problem still existing. What a violation is, and what it is not. From NYC Department of Buildings, DOB Violations (3h2n-5cm9), accessed Sep 10, 2026.
What is recorded here
New York City's Building Identification Number helps connect filings that may use different application numbers or describe different scopes of work. The records below are grouped because they publish BIN 2003883. They should not be read as a single construction project unless the underlying filings say so.
The matched set includes 5 alteration filing. Its latest status categories are 1 approved, 4 under review. Each filing page preserves its own status, dates, scope and source identifier.
Highest recorded values may come from different filings and must not be combined into one proposed project. Open the individual filings below for their exact scope. Values outside the publication's conservative data-quality bounds are withheld pending source review.
Address alerts
Get an email when NewYorkDaily detects a material change in the public DOB records associated with 455 Southern Boulevard.
Confirmation is required. Alerts describe source-data changes, not confirmed construction activity. Unsubscribe at any time. Privacy
Recorded history
Every dated event the city has published for this building, from all 5 matched filings, in the order it was recorded. A date marks what entered the public record, not what happened on site.
Sh/hero hs - for temporary construction equipment(emergency shed) submitting on behalf of contractor, in conjunction with llw nochange in use, occupancy or egress. Filing X01248152-I1.
Filing X01248152-I1 reached an approved status.
DOB lists a first permit date for X01248152-I1. That is not by itself confirmation of activity on site.
Refer to M001 "Summary of work removal' and "summary of work new" for MHVAC scope of work. Filing X01433756-S2.
Replace Courtyard Plaza area Drains and related piping. Replace areaway #2 drain and related piping. Replace all roof drains and related piping and relocate selected vents on same roof. Filing X01433756-S3.
Repair spalling deteriorated concrete ceiling slab and beams on cellar. and penthouses throughout the building. Repair roof spandrel beams rebuilt parapet and replace selected lintels. Filing X01433756-S1.
Replace in existing roof and parapet. Repair exterior masonry and deteriorated lintes. Repair and replace plaza deck waterproofing and pavement. Provide interior wall concrete wall and ceiling repairs. Repair and paint interior finish. BLKH Win Door. Filing X01433756-I1.
The latest status recorded for X01433756-I1 is “Plan Examiner Review.”
The latest status recorded for X01433756-S1 is “Plan Examiner Review.”
The latest status recorded for X01433756-S2 is “Plan Examiner Review.”
The latest status recorded for X01433756-S3 is “Plan Examiner Review.”
The latest status recorded for X01248152-I1 is “Permit Entire.”